Schematic

image0

Instructions

  • The two coils provided with ExpEYES are used as the primay and secondary.
  • WG output is applied to the primary and voltage is monitored on A1.
  • Induced voltage on secondary is monitored on A2.
  • Make connections and keep the coils close and parallel.
  • Insert some ferromagnetic material through the coils to increase the voltage induced on the secondary coil.